Objectives: To determine the profiles of patients who have had incidents or accidents after intravenous injection of iodinated contrast media (ICP).Material and methods: Prospective descriptive and analytical study extending over 12 months.Results: Incidents and reactions to ICP were observed after ICP injection in 150 patients out of a total of 5762 patients (2.60%). In the study population, women accounted for 52.7% of patients (79 cases); extravasation of ICP and minor reactions were most often observed in female subjects (63 women / 54 men and 20 women / 16 men); the most affected age group is 60 to 69; minor reactions were observed only at the age of 30 years. When the flow rate was greater than 2ml / s ICP injected, 78.77% (115 patients) had extravasation. ICP was extravagated in all cases where the venous route had been placed for at least 24 hours (89 patients) or on the back of the hand (65 patients). In 68.69% when epi-vein was used for the venous route (68 patients), extravasation was noted.Conclusion: Incidents and accidents related to ICP injection are not negligible in our environments.


 


Résumé


Objectifs : Déterminer les profils des patients ayant eu des incidents ou accidents après injection intraveineuse de produits de contraste iodé (PCI). 


Matériel et méthodes : Etude prospective descriptive et analytique s’étendant sur 12 mois.


Résultats : Les incidents et réactions au PCI avaient été observés après injection de PCI chez 150 patients sur un ensemble de 5762 patients (2,60 %). Dans la population étudiée, les femmes représentaient 52,7% des patients (79 cas) ; l’extravasation du PCI et  les réactions mineures avaient été observées le plus souvent chez les sujets de sexe féminin (63 femmes/54 hommes et 20 femmes/16 hommes) ; la tranche d’âge la plus touchée est celle de 60 à 69 ans ; les réactions mineures n’avaient été observées qu’à partir de l’âge de 30 ans. Lorsque le débit était supérieur à 2ml/s de PCI injecté, 78,77%   (115 patients) avaient présenté une extravasation. On avait noté une extravasation de PCI dans tous les cas où la voie veineuse avait été placée au moins depuis 24 heures (89 patients) ou au dos de la main (65 patients). Dans 68,69% lorsque l’épi-veine avait été utilisée pour la voie veineuse (68 patients) il avait été noté une extravasation.


Conclusion : Les incidents et accidents liées à l’injection de PCI ne sont pas négligeables dans nos milieux. 

Keywords

Produits de contraste iodés tomodensitométrie injecteur automatique extravasation Togo

Article Details

How to Cite
admin, admin, SONHAYE Lantam, KOLOU Bérésa, AMADOU Abdoulatif, GBANDÉ Pihou, DAGBÉ Massaga, BADJOGOU Kodjovi Emmanuel, TCHAOU Masamaesso, N’TIMON Bidamin, ADAMBOUNOU Kokou, & ADJÉNOU Komlanvi. (2020). Aspect épidémiologique et facteurs favorisants les incidents et accidents liés à l’injection de produits de contraste iodés lors d’une tomodensitométrie. Journal Africain d’Imagerie Médicale (J Afr Imag Méd)., 11(4). https://doi.org/10.55715/jaim.v11i4.50

References

  1. Imagerie médicale : Produits de contraste [Internet]. Elsevier Masson, le blog. 2016 [cité 28 sept 2018]. Disponible sur: http://www.blog-elsevier-masson.fr/2016/09/imagerie-medicale-produits-de-contraste/
  2. Société Française de Radiologie. Fiche Information Patients : utilisation des produits de contraste en Imagerie Médicale. [Internet]. SFR. 2010 [cité 28 sept 2018].Disponible sur:http://www.sfrnet.org/sfr/professionnels/1-fiche-information-patients/produits-de-contraste/
  3. Clément O. le point sur... - Iatrogénie des produits de contraste. /data/revues/02210363/00865-C2/567/ [Internet]. 10 avr 2008 [cité 28 sept 2018]; Disponible sur: http://www.em-consulte.com/en/article/138789
  4. Katayama H, Yamaguchi K, Kozuka T, Takashima T, Seez P, Matsuura K. Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media. Radiology. 1 juin 1990;175(3):621‑8.
  5. Dewachter P, Mouton-Faivre C, Laroche D, Clément O. Allergie immédiate aux produits de contraste iodés et prévention des réactions. La Revue de Médecine Interne. 1 oct 2009;30(10):872‑81.
  6. Dewachter P, Mouton-Faivre C. Prévention des réactions sévères après injection de produits de contraste iodés : revue de la littérature. /data/revues/02210363/00840005/535/ [Internet]. 19 mars 2008 [cité 28 sept 2018]; Disponible sur: http://www.em-consulte.com/en/article/121540
  7. Hwang EJ, Shin C-I, Choi YH, Park CM. Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans. Eur Radiol. 1 déc 2018;28(12):5368‑75.
  8. Jagdish Singh. Iodinated contrast media and their adverse reactions. Journal of Nuclear Medicine Technology. 2008;36(2):69-74.
  9. Federle MP, Chang PJ, Confer S, Ozgun B. Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology. 1 mars 1998;206(3):637‑40.
  10. Cochran ST, Bomyea K, Sayre JW. Trends in Adverse Events After IV Administration of Contrast Media. American Journal of Roentgenology. 1 juin 2001;176(6):1385‑8.
  11. Conseil des enseignants de radiologie de france. Technologie de base en radiologie et imagerie medicale. 1ere éd. 1995.
  12. Miles SG, Rasmussen JF, Litwiller T, Osik A. Safe use of an intravenous power injector for CT: experience and protocol. Radiology. 1 juill 1990;176(1):69‑70.
  13. Caro JJ, Trindade E, McGregor M. The risks of death and of severe nonfatal reactions with high- vs low-osmolality contrast media: a meta-analysis. American Journal of Roentgenology. 1 avr 1991;156(4):825‑32.
  14. Cashman JD, McCredie J, Henry DA. Intravenous contrast media: use and associated mortality. Med J Aust. nov 1991;155(9):618‑23.
  15. Ansell G. Adverse Reactions to Contrast Agents Scope of Problem. Investigative Radiology. avr 1990;25(4):381.
  16. Bush WH, Swanson DP. Acute reactions to intravascular contrast media: types, risk factors, recognition, and specific treatment. American Journal of Roentgenology. 1 déc 1991;157(6):1153‑61.
  17. Shaqdan K, Aran S, Thrall J, Abujudeh H. Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: A report on 502,391 injections. Clinical Radiology. 1 déc 2014;69(12):1264‑72.
  18. Wienbeck S, Fischbach R, Kloska SP, Seidensticker P, Osada N, Heindel W, et al. Prospective Study of Access Site Complications of Automated Contrast Injection With Peripheral Venous Access in MDCT. American Journal of Roentgenology. 1 oct 2010;195(4):825‑9.
  19. Moreno CC, Pinho D, Nelson RC, Sahani DV, Jenkins M, Zabrycki M, et al. Lessons Learned from 118,970 Multidetector Computed Tomographic Intravenous Contrast Material Administrations: Impact of Catheter Dwell Time and Gauge, Catheter Location, Rate of Contrast Material Administration, and Patient Age and Sex on Volume of Extravasate. Journal of Computer Assisted Tomography. avr 2013;37(2):286.
  20. Wang CL, Cohan RH, Ellis JH, Caoili EM, Wang G, Francis IR. Frequency, Outcome, and Appropriateness of Treatment of Nonionic Iodinated Contrast Media Reactions. American Journal of Roentgenology. 1 août 2008;191(2):409‑15.
  21. William et al. adverse reactons to contrast media. 1980;
  22. Singh J, Daftary A. Iodinated Contrast Media and Their Adverse Reactions. J Nucl Med Technol. 6 janv 2008;36(2):69‑74.
  23. Kim SM, Cook KH, Lee IJ, Park DH, Park MC. Computed tomography contrast media extravasation: treatment algorithm and immediate treatment by squeezing with multiple slit incisions. International Wound Journal. 2017;14(2):430‑4.
  24. Ding S, Meystre NR, Campeanu C, Giuseppe G. the effectiveness of interventions to prevent or reduce Contrast Media Extravasations among patients undergoing computerized tomography scanning: a systematic review protocol. Jbi Database of Systematic Reviews and Implementation Reports. 1 août 2014;12(8):52‑63.
  25. Goutos I, Cogswell LK, Giele H. Extravasation injuries: a review. J Hand Surg Eur Vol. 1 oct 2014;39(8):808‑18.
  26. Sum W, Ridley LJ. Recognition and management of contrast media extravasation. Australasian Radiology. 2006;50(6):549‑52.
  27. Palmer FJ. The RACR Survey of Intravenous Contrast Media Reactions Final Report. Australasian Radiology. 1988;32(4):426‑8.
  28. Hwang EJ, Shin C-I, Choi YH, Park CM. Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans. Eur Radiol. 1 déc 2018;28(12):5368‑75.
  29. Bonardel G, Barrau C, Soussan M, D’Estanque E, Erra B, Etard C, et al. Illustrations pratiques – Produits de contraste iodés (PCI). Médecine Nucléaire. 1 sept 2018;42(5):391‑9.
  30. Namasivayam S, Kalra MK, Torres WE, Small WC. Adverse reactions to intravenous iodinated contrast media: a primer for radiologists. Emerg Radiol. 1 juill 2006;12(5):210‑5.
  31. Kim SR, Lee JH, Park KH, Park HJ, Park JW. Varied incidence of immediate adverse reactions to low-osmolar non-ionic iodide radiocontrast media used in computed tomography. Clinical & Experimental Allergy. 2017;47(1):106‑12.
  32. McClennan BL. Preston M. Hickey memorial lecture. Ionic and nonionic iodinated contrast media: evolution and strategies for use. American Journal of Roentgenology. 1 août 1990;155(2):225‑33.
  33. Lasser EC, Berry CC, Mishkin MM, Williamson B, Zheutlin N, Silverman JM. Pretreatment with corticosteroids to prevent adverse reactions to nonionic contrast media. American Journal of Roentgenology. 1 mars 1994;162(3):523‑6.
  34. Park S-J, Kang D-Y, Sohn K-H, Yoon S-H, Lee W, Choi Y-H, et al. Immediate Mild Reactions to CT with Iodinated Contrast Media: Strategy of Contrast Media Readministration without Corticosteroids. Radiology. 22 mai 2018;288(3):710‑6.
  35. Davenport MS, Wang CL, Bashir MR, Neville AM, Paulson EK. Rate of Contrast Material Extravasations and Allergic-like Reactions: Effect of Extrinsic Warming of Low-Osmolality Iodinated CT Contrast Material to 37°C. Radiology. 1 févr 2012;262(2):475‑84.
  36. Shuman WP, Adam JL, Schoenecker SA, Tazioli PR, Moss AA. Use of a power injector during dynamic computed tomography. J Comput Assist Tomogr. 1986;10(6):1000‑2.
  37. Miles SG, Rasmussen JF, Litwiller T, Osik A. Safe use of an intravenous power injector for CT: experience and protocol. Radiology. 1 juill 1990;176(1):69‑70.
  38. Sinan T, Al-Khawari H, Chishti FA, Saeed OMA, Sheikh M. Contrast Media Extravasation: Manual versus Power Injector. MPP. 2005;14(2):107‑10.
  39. Sistrom CL, Gay SB, Peffley L. Extravasation of iopamidol and iohexol during contrast-enhanced CT:

Most read articles by the same author(s)

<< < 3 4 5 6 7 8